UNIVERSAL METER UT-181A UNI-T

The UT-181A is a universal digital meter used to measure: voltage, current, resistance, capacity, frequency, temperature and checking the correct operation of diodes; Main features: True RMS – accurate measurement of the RMS current and voltage for any waveform, Freezing the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bargraph, Possibility to save readings, access saved results and send them to a computer using the USB interface Large, easy to read LCD graphic display with backlight, </span>;






























































DC voltage measurement: 60 mV ± (0.025% + 20)  @ 0.001 mV ,
600 mV ± (0.025% + 5)  @ 0.01 mV ,
6 V ± (0.025% + 5)  @ 0.0001 V ,
60 V ± (0.025% + 5)  @ 0.001 V ,
600 V ± (0.03% + 5)  @ 0.01 V ,
1000 V ± (0.03% + 5)  @ 0.1 V
AC voltage measurement:
  • 60 mV @ 0.001 mV :
  • ± (0.6% + 60)  @ 45 Hz … 1 kHz ,
    ± (1.2% + 60)  @ >1 kHz … 10 kHz ,
    ± (3.0% + 60)  @ >10 kHz … 20 kHz ,
    ± (4.0% + 60)  @ >20 kHz … 100 kHz ,

  • 600 mV @ 0.01 mV :
  • ± (0.3% + 30)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz
    ± (3.0% + 40)  @ >10 kHz … 20 kHz
    ± (4.0% + 40)  @ >20 kHz … 100 kHz ,

  • 6 V @ 0.0001 V :
  • ± (0.3% + 30)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz
    ± (3.0% + 40)  @ >10 kHz … 20 kHz
    ± (4.0% + 40)  @ >20 kHz … 100 kHz ,

  • 60 V @ 0.001 V :
  • ± (0.3% + 30)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz
    ± (3.0% + 40)  @ >10 kHz … 20 kHz
    ± (4.0% + 40)  @ >20 kHz … 100 kHz

  • 600 V @ 0.01 V :
  • ± (0.3% + 30)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz ,
    ± (3.0% + 40)  @ >10 kHz … 20 kHz ,

  • 1000 V @ 0.1 V :
  • ± (0.6% + 30)  @ 45 Hz … 1 kHz
    ± (3.0% + 40)  @ >1 kHz … 5 kHz ,
    ± (6.0% + 40)  @ >5 kHz … 10 kHz
    DC current measurement: 600 µA ± (0.08% + 20)  @ 0.01 µA ,
    6000 µA ± (0.08% + 10)  @ 0.1 µA ,
    60 mA ± (0.08% + 20)  @ 0.001 mA ,
    600 mA ± (0.15% + 10)  @ 0.01 mA ,
    10 A ± (0.5% + 10)  @ 0.001 A
    AC current measurement:
  • 600 µA @ 0.01 µA :
  • ± (0.6% + 40)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz

  • 6000 µA @ 0.1 µA :
  • ± (0.6% + 20)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz

  • 60 mA @ 0.001 mA :
  • ± (0.6% + 40)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz

  • 600 mA @ 0.01 mA :
  • ± (0.6% + 20)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz

  • 10 A @ 0.001 A :
  • ± (1.0% + 20)  @ 45 Hz … 1 kHz
    ± (3.0% + 40)  @ >1 kHz … 10 kHz
    Resistance measurement: 600 Ω ± (0.05% + 10)  @ 0.01 Ω ,
    6 kΩ ± (0.05% + 2)  @ 0.0001 kΩ ,
    60 kΩ ± (0.05% + 2)  @ 0.001 kΩ ,
    600 kΩ ± (0.05% + 2)  @ 0.01 kΩ ,
    6 MΩ ± (0.3% + 10)  @ 0.0001 MΩ ,
    60 MΩ ± (2.0% + 10)  @ 0.001 MΩ
    Capacitance measurement: 6 nF ± (3.0% + 10)  @ 0.001 nF ,
    60 nF ± (2.5% + 5)  @ 0.01 nF ,
    600 nF ± (2.0% + 5)  @ 0.1 nF ,
    6 µF ± (2.0% + 5)  @ 0.001 µF ,
    60 µF ± (2.0% + 5)  @ 0.01 µF
    600 µF ± (2.0% + 5)  @ 0.1 µF ,
    6 mF ± (5.0% + 5)  @ 0.001 mF ,
    60 mF @ 0.01 mF – visual measurement
    Inductance measurement: ''
    Frequency measurement: 60 Hz ± (0.02% + 8)  @ 0.001 Hz ,
    600 Hz ± (0.01% + 5)  @ 0.01 Hz ,
    6 kHz ± (0.01% + 5)  @ 0.0001 kHz ,
    60 kHz ± (0.01% + 5)  @ 0.001 kHz ,
    600 kHz ± (0.01% + 5)  @ 0.01 kHz ,
    6 MHz ± (0.01% + 5)  @ 0.0001 MHz ,
    60 MHz ± (0.01% + 5)  @ 0.001 MHz
    Square-wave signal duty ratio measurement: 10 % … 90 % ± (1.2% + 30)  @ 0.01 %
    Pulse width measurement: 250 ms ± (1.2% + 30)  @ 0.001 ms … 0.01 ms
    Temperature measurement:
  • °C
  • -40  … 40 °C ± (2.0% + 30)  @ 0.1 °C
    >40  … 400 °C ± (1.0% + 30)  @ 0.1 °C
    >400  … 1000 °C ± 2.5%  @ 0.1 °C,
  • °F
  • -40  … 104 °F ± (2.5% + 50)  @ 0.1 °F
    >104  … 752 °F ± (1.5% + 50)  @ 0.1 °F
    >752  … 1832 °F ± 2.5%  @ 0.1 °F
    Automatic change of measuring ranges: ''
    hFE: ''
    Diode test: ''
    Sound signal of the continuity test: ''
    Checking TTL logic states: ''
    RS-232: ''
    USB: ''
    Main features:
  • True RMS – accurate measurement of the RMS current and voltage for any waveform,
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL – relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, easy to read LCD graphic display with backlight,
  • The ability to draw a trend graph of changes in the measured value over time based on the data stored in the device from continuous measurement,
  • Save to 20000 measurement results in the device memory,
  • Voltage level measurement (dBV/dBm),
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes a practical case
  • Power supply: Built-in battery 7.4V / 2200mAh, the set includes a 10V / 500mA power supply and a power adapter for charging the battery
    Weight: 0.62 kg
    Dimensions: 226  x 104  x 63 mm
    Manufacturer / Brand: UNI-T
    Guarantee: 2 years

    The UT-181A is a universal digital meter used to measure: voltage, current, resistance, capacity, frequency, temperature and checking the correct operation of diodes

    The meter has the function of automatic change of measuring ranges, as well as the relative measurement mode


    The device enables the graphical presentation of the trend of changes in the measured value

    Producent UNI-T

    EAN 5901890013338

     

    UNIVERSAL METER UT-71A UNI-T

    The UT-71A is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes; Main features: Freezing the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bargraph, Possibility to save readings, access saved results and send them to a computer using the USB interface </span>;

























































    DC voltage measurement: 200 mV ± (0.1% + 8)  @ 0.01 mV ,
    2 V ± (0.1% + 8)  @ 0.0001 V ,
    20 V ± (0.1% + 8)  @ 0.001 V ,
    200 V ± (0.1% + 8)  @ 0.01 V ,
    1000 V ± (0.15% + 8)  @ 0.1 V
    AC voltage measurement:
  • 2 V @ 0.0001 V :
  • ± (0.8% + 40)  @ 45 Hz … 1 kHz
    ± (3% + 40)  @ 1 kHz … 10 kHz
    ± (7% + 40)  @ 10 kHz … 100 kHz

  • 20 V @ 0.001 V :
  • ± (0.8% + 40)  @ 45 Hz … 1 kHz
    ± (3% + 40)  @ 1 kHz … 10 kHz
    ± (7% + 40)  @ 10 kHz … 100 kHz

  • 200 V @ 0.01 V :
  • ± (0.8% + 40)  @ 45 Hz … 1 kHz
    ± (5% + 40)  @ 1 kHz … 10 kHz

  • 1000 V @ 0.1 V :
  • ± (1.5% + 40)  @ 45 Hz … 1 kHz
    ± (6% + 40)  @ 1 kHz … 5 kHz
    ± (10% + 40)  @ 5 kHz … 100 kHz
    DC current measurement: 200 µA ± (0.2% + 20)  @ 0.01 µA ,
    2000 µA ± (0.2% + 20)  @ 0.1 µA ,
    20 mA ± (0.2% + 20)  @ 0.001 mA ,
    200 mA ± (0.2% + 20)  @ 0.01 mA ,
    10 A ± (0.8% + 30)  @ 0.001 mA
    AC current measurement:
  • 200 µA @ 0.01 µA :
  • ± (1% + 15)  @ 45 Hz … 1 kHz
    ± (2% + 40)  @ 1 kHz … 10 kHz

  • 2000 µA @ 0.1 µA :
  • ± (1% + 15)  @ 45 Hz … 1 kHz
    ± (2% + 40)  @ 1 kHz … 10 kHz

  • 20 mA @ 0.001 mA :
  • ± (1% + 15)  @ 45 Hz … 1 kHz
    ± (2% + 40)  @ 1 kHz … 10 kHz

  • 200 mA @ 0.01 mA :
  • ± (1% + 15)  @ 45 Hz … 1 kHz
    ± (2% + 40)  @ 1 kHz … 10 kHz

  • 10 A @ 0.001 A :
  • ± (2% + 20)  @ 45 Hz … 1 kHz
    ± (2% + 40)  @ 1 kHz … 10 kHz
    Resistance measurement: 200 Ω ± (0.5% + 20) + test leads resistance @ 0.01 Ω ,
    2 kΩ ± (0.5% + 20)  @ 0.0001 kΩ ,
    20 kΩ ± (0.5% + 20)  @ 0.001 kΩ ,
    200 kΩ ± (1% + 20)  @ 0.01 kΩ ,
    2 MΩ ± (1% + 40)  @ 0.0001 MΩ ,
    20 MΩ ± (1.5% + 40)  @ 0.001 MΩ
    Capacitance measurement: 20 nF ± (1.5% + 20) + capacity of test leads @ 0.001 nF ,
    200 nF ± (1.5% + 20)  @ 0.01 nF ,
    2 µF ± (1.5% + 20)  @ 0.0001 µF ,
    20 µF ± (1.5% + 40)  @ 0.001 µF ,
    400 µF ± (1.5% + 40)  @ 0.01 µF ,
    2 mF ± (5% + 40)  @ 0.0001 mF
    20 mF @ 0.001 mF
    Inductance measurement: ''
    Frequency measurement: 20 Hz ± (0.1% + 15)  @ 0.001 Hz
    200 Hz ± (0.1% + 15)  @ 0.01 Hz
    2 kHz ± (0.1% + 15)  @ 0.0001 Hz
    20 kHz ± (0.1% + 15)  @ 0.001 Hz
    200 kHz ± (0.1% + 15)  @ 0.01 Hz
    2 MHz ± (0.1% + 15)  @ 0.0001 MHz
    20 MHz ± (0.1% + 15)  @ 0.001 Hz
    200 MHz @ 0.01 MHz
    Temperature measurement: ''
    Automatic change of measuring ranges: ''
    hFE: ''
    Diode test: ''
    Sound signal of the continuity test: ''
    Checking TTL logic states: ''
    RS-232: ''
    USB: ''
    Main features:
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL – relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, readable LCD display with backlight,
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes short test leads with crocodile clips,
  • The set includes a practical case
  • Power supply: 9V, type 6F22 battery – included
    Weight: 0.35 kg
    Dimensions: 203  x 93  x 40 mm
    Manufacturer / Brand: UNI-T
    Guarantee: 2 years

    The UT-71A is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes

    The meter has the function of automatic change of measuring ranges, as well as the relative measurement mode

    Producent UNI-T

    EAN 5901436741084

     

    UNIVERSAL METER UT-71D UNI-T

    The UT-71D is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes; Main features: Freezing the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bargraph, Possibility to save readings, access saved results and send them to a computer using the USB interface </span>;

























































    DC voltage measurement: 400 mV ± (0.025% + 5)  @ 0.01 mV ,
    4 V ± (0.05% + 5)  @ 0.0001 V ,
    40 V ± (0.05% + 5)  @ 0.001 V ,
    400 V ± (0.05% + 5)  @ 0.01 V ,
    1000 V ± (0.1% + 8)  @ 0.1 V
    AC voltage measurement:
  • 4 V @ 0.0001 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (3% + 30)  @ 1 kHz … 10 kHz
    ± (6% + 30)  @ 10 kHz … 100 kHz

  • 40 V @ 0.001 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (3% + 30)  @ 1 kHz … 10 kHz
    ± (6% + 30)  @ 10 kHz … 100 kHz

  • 400 V @ 0.01 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (5% + 30)  @ 1 kHz … 10 kHz

  • 1000 V @ 0.1 V :
  • ± (1% + 30)  @ 45 Hz … 1 kHz
    ± (5% + 30)  @ 1 kHz … 5 kHz
    ± (10% + 30)  @ 5 kHz … 100 kHz
    DC current measurement: 400 µA ± (0.1% + 15)  @ 0.01 µA ,
    4000 µA ± (0.1% + 15)  @ 0.1 µA ,
    40 mA ± (0.15% + 15)  @ 0.001 mA ,
    400 mA ± (0.15% + 15)  @ 0.01 mA ,
    10 A ± (0.5% + 30)  @ 0.001 A
    AC current measurement:
  • 400 µA @ 0.01 µA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 4000 µA @ 0.1 µA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 40 mA @ 0.001 mA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 400 mA @ 0.01 mA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 10 A @ 0.001 A :
  • ± (1.5% + 20)  @ 45 Hz … 1 kHz
    ± (5% + 40)  @ 1 kHz … 10 kHz
    Resistance measurement: 400 Ω ± (0.3% + 8) + test leads resistance @ 0.01 Ω ,
    4 kΩ ± (0.3% + 8)  @ 0.0001 kΩ ,
    40 kΩ ± (0.3% + 8)  @ 0.001 kΩ ,
    400 kΩ ± (0.5% + 20)  @ 0.01 kΩ ,
    4 MΩ ± (1% + 40)  @ 0.0001 MΩ ,
    40 MΩ ± (1.5% + 40)  @ 0.001 MΩ
    Capacitance measurement: 40 nF ± (1% + 20) + capacity of test leads @ 0.001 nF ,
    400 nF ± (1% + 20)  @ 0.01 nF ,
    4 µF ± (1% + 20)  @ 0.0001 µF ,
    40 µF ± (1% + 20)  @ 0.001 µF ,
    400 µF ± (1.2% + 20)  @ 0.01 µF ,
    4 mF ± (5% + 20)  @ 0.0001 mF
    40 mF @ 0.001 mF
    Inductance measurement: ''
    Frequency measurement: 40 Hz ± (0.01% + 8)  @ 0.001 Hz
    400 Hz ± (0.01% + 8)  @ 0.01 Hz
    4 kHz ± (0.01% + 8)  @ 0.0001 Hz
    40 kHz ± (0.01% + 8)  @ 0.001 Hz
    400 kHz ± (0.01% + 8)  @ 0.01 Hz
    4 MHz ± (0.01% + 8)  @ 0.0001 MHz
    40 MHz ± (0.01% + 8)  @ 0.001 Hz
    400 MHz @ 0.01 MHz – visual measurement
    Temperature measurement:
  • °C
  • -40  … 40 °C ± (3% + 30)  @ 0.1 °C
    40  … 400 °C ± (1% + 30)  @ 0.1 °C
    400  … 1000 °C ± 2.5%  @ 0.1 °C,
  • °F
  • -40  … 32 °F ± (4% + 50)  @ 0.1 °F
    32  … 752 °F ± (1.5% + 50)  @ 0.1 °F
    752  … 1832 °F ± 3%  @ 0.1 °F
    Automatic change of measuring ranges: ''
    hFE: ''
    Diode test: ''
    Sound signal of the continuity test: ''
    Checking TTL logic states: ''
    RS-232: ''
    USB: ''
    Main features:
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL – relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, readable LCD display with backlight,
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes short test leads with crocodile clips,
  • The set includes a practical case
  • Power supply: 9V, type 6F22 battery – included
    Weight: 0.38 kg
    Dimensions: 203  x 93  x 40 mm
    Manufacturer / Brand: UNI-T
    Guarantee: 2 years

    The UT-71D is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes

    The meter has the function of automatic change of measuring ranges, as well as the relative measurement mode

    Producent UNI-T

    EAN 5901436741091

     

    UNIVERSAL METER UT-71E UNI-T

    The UT-71E is a universal digital meter used to measure: voltage, current, resistance, power, capacity, frequency, temperature and checking the correct operation of diodes; Main features: Freezing the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bargraph, Possibility to save readings, access saved results and send them to a computer using the USB interface </span>;




























































    DC voltage measurement: 400 mV ± (0.025% + 5)  @ 0.01 mV ,
    4 V ± (0.05% + 5)  @ 0.0001 V ,
    40 V ± (0.05% + 5)  @ 0.001 V ,
    400 V ± (0.05% + 5)  @ 0.01 V ,
    1000 V ± (0.1% + 8)  @ 0.1 V
    AC voltage measurement:
  • 4 V @ 0.0001 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (3% + 30)  @ 1 kHz … 10 kHz
    ± (6% + 30)  @ 10 kHz … 100 kHz

  • 40 V @ 0.001 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (3% + 30)  @ 1 kHz … 10 kHz
    ± (6% + 30)  @ 10 kHz … 100 kHz

  • 400 V @ 0.01 V :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (5% + 30)  @ 1 kHz … 10 kHz

  • 1000 V @ 0.1 V :
  • ± (1% + 30)  @ 45 Hz … 1 kHz
    ± (5% + 30)  @ 1 kHz … 5 kHz
    ± (10% + 30)  @ 5 kHz … 100 kHz
    DC current measurement: 400 µA ± (0.1% + 15)  @ 0.01 µA ,
    4000 µA ± (0.1% + 15)  @ 0.1 µA ,
    40 mA ± (0.15% + 15)  @ 0.001 mA ,
    400 mA ± (0.15% + 15)  @ 0.01 mA ,
    10 A ± (0.5% + 30)  @ 0.001 A
    AC current measurement:
  • 400 µA @ 0.01 µA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 4000 µA @ 0.1 µA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 40 mA @ 0.001 mA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 400 mA @ 0.01 mA :
  • ± (0.7% + 15)  @ 45 Hz … 1 kHz
    ± (1% + 40)  @ 1 kHz … 10 kHz

  • 10 A @ 0.001 A :
  • ± (1.5% + 20)  @ 45 Hz … 1 kHz
    ± (5% + 40)  @ 1 kHz … 10 kHz
    Resistance measurement: 400 Ω ± (0.3% + 8) + test leads resistance @ 0.01 Ω ,
    4 kΩ ± (0.3% + 8)  @ 0.0001 kΩ ,
    40 kΩ ± (0.3% + 8)  @ 0.001 kΩ ,
    400 kΩ ± (0.5% + 20)  @ 0.01 kΩ ,
    4 MΩ ± (1% + 40)  @ 0.0001 MΩ ,
    40 MΩ ± (1.5% + 40)  @ 0.001 MΩ
    Capacitance measurement: 40 nF ± (1% + 20) + capacity of test leads @ 0.001 nF ,
    400 nF ± (1% + 20)  @ 0.01 nF ,
    4 µF ± (1% + 20)  @ 0.0001 µF ,
    40 µF ± (1% + 20)  @ 0.001 µF ,
    400 µF ± (1.2% + 20)  @ 0.01 µF ,
    4 mF ± (5% + 20)  @ 0.0001 mF
    40 mF @ 0.001 mF
    Inductance measurement: ''
    Frequency measurement: 40 Hz ± (0.01% + 8)  @ 0.001 Hz
    400 Hz ± (0.01% + 8)  @ 0.01 Hz
    4 kHz ± (0.01% + 8)  @ 0.0001 Hz
    40 kHz ± (0.01% + 8)  @ 0.001 Hz
    400 kHz ± (0.01% + 8)  @ 0.01 Hz
    4 MHz ± (0.01% + 8)  @ 0.0001 MHz
    40 MHz ± (0.01% + 8)  @ 0.001 Hz
    400 MHz @ 0.01 MHz – visual measurement
    Temperature measurement:
  • °C
  • -40  … 40 °C ± (3% + 30)  @ 0.1 °C
    40  … 400 °C ± (1% + 30)  @ 0.1 °C
    400  … 1000 °C ± 2.5%  @ 0.1 °C,
  • °F
  • -40  … 32 °F ± (4% + 50)  @ 0.1 °F
    32  … 752 °F ± (1.5% + 50)  @ 0.1 °F
    752  … 1832 °F ± 3%  @ 0.1 °F
    Power measurement:
  • Nominal power : 2500 W ± (2% + 10)  @ 0.1 W,
  • Apparent Power : 2500 VA ± (2% + 10)  @ 0.1 VA,
  • Power factor (cosφ) : 0 … 1  ± (1% + 10)  @ 0.001,
  • Automatic change of measuring ranges: ''
    hFE: ''
    Diode test: ''
    Sound signal of the continuity test: ''
    RS-232: ''
    Checking TTL logic states: ''
    USB: ''
    Main features:
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL – relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, readable LCD display with backlight,
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes short test leads with crocodile clips,
  • The set includes a practical case
  • Power supply: 9V, type 6F22 battery – included
    Weight: 0.38 kg
    Dimensions: 203  x 93  x 40 mm
    Manufacturer / Brand: UNI-T
    Guarantee: 2 years

    The UT-71E is a universal digital meter used to measure: voltage, current, resistance, power, capacity, frequency, temperature and checking the correct operation of diodes

    The meter has the function of automatic change of measuring ranges, as well as the relative measurement mode

    Producent UNI-T

    EAN 5901436741107

     

    UNIVERSAL METER UT-171B UNI-T

    The UT-171B is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes; Main features: True RMS – accurate measurement of the RMS current and voltage for any waveform, NCV – electric field detection function, Freezing the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bargraph, Possibility to save readings, access saved results and send them to a computer using the USB interface </span>;

























































    DC voltage measurement: 600 mV ± (0.025% + 5)  @ 10 µV ,
    6 V ± (0.025% + 5)  @ 100 µV ,
    60 V ± (0.025% + 5)  @ 1 mV ,
    600 V ± (0.03% + 5)  @ 10 mV ,
    1000 V ± (0.03% + 5)  @ 100 mV
    AC voltage measurement:
  • 600 mV @ 10 µV :
  • ± (0.4% + 40)  @ 45 Hz … 1 kHz
    ± (5.0% + 40)  @ >1 kHz … 10 kHz
    ± (5.5% + 40)  @ >10 kHz … 20 kHz
    ± (8.0% + 40)  @ >20 kHz … 100 kHz

  • 6 V @ 100 µV :
  • ± (0.4% + 40)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz
    ± (3.0% + 40)  @ >10 kHz … 20 kHz
    ± (8.0% + 40)  @ >20 kHz … 100 kHz

  • 60 V @ 1 mV :
  • ± (0.4% + 40)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 10 kHz
    ± (3.0% + 40)  @ >10 kHz … 20 kHz
    ± (6.0% + 40)  @ >20 kHz … 100 kHz

  • 600 V @ 10 mV :
  • ± (0.4% + 30)  @ 45 Hz … 1 kHz
    ± (3.0% + 40)  @ >1 kHz … 10 kHz

  • 1000 V @ 100 mV :
  • ± (0.6% + 40)  @ 45 Hz … 1 kHz
    ± (3.5% + 40)  @ >1 kHz … 10 kHz
    DC current measurement: 600 µA ± (0.25% + 20)  @ 0.01 µA ,
    6000 µA ± (0.25% + 2)  @ 0.1 µA ,
    60 mA ± (0.15% + 10)  @ 1 µA ,
    600 mA ± (0.15% + 10)  @ 10 µA ,
    6 A ± (0.5% + 10)  @ 100 µA
    10 A ± (0.5% + 2)  @ 1 mA
    AC current measurement:
  • 600 µA @ 0.01 µA :
  • ± (0.75% + 20)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 20 kHz
    ± (6.0% + 40)  @ >20 kHz … 100 kHz

  • 6000 µA @ 0.1 µA :
  • ± (0.75% + 20)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 20 kHz
    ± (3.0% + 40)  @ >20 kHz … 100 kHz

  • 60 mA @ 1 µA :
  • ± (0.75% + 20)  @ 45 Hz … 1 kHz
    ± (1.2% + 40)  @ >1 kHz … 20 kHz
    ± (9.0 + 40)  @ >20 kHz … 100 kHz

  • 600 mA @ 10 µA :
  • ± (0.75% + 20)  @ 45 Hz … 1 kHz
    ± (1.5% + 10)  @ >1 kHz … 20 kHz
    ± (4.0% + 40)  @ >20 kHz … 100 kHz

  • 6 A @ 100 µA :
  • ± (1.5% + 20)  @ 45 Hz … 1 kHz
    ± (6.0% + 40)  @ >1 kHz … 20 kHz
  • 10 A @ 1 mA :
  • ± (1.5% + 5)  @ 45 Hz … 1 kHz
    ± (5.0% + 10)  @ >1 kHz … 20 kHz
    Resistance measurement: 600 Ω ± (0.05% + 10)  @ 0.01 Ω ,
    6 kΩ ± (0.05% + 2)  @ 0.1 Ω ,
    60 kΩ ± (0.05% + 2)  @ 1 Ω ,
    600 kΩ ± (0.05% + 2)  @ 10 Ω ,
    6 MΩ ± (0.15% + 5)  @ 100 Ω ,
    60 MΩ ± (3.0% + 2)  @ 1 kΩ
    Capacitance measurement: 6 nF ± (3.0% + 30) + capacity of test leads @ 1 pF ,
    60 nF … 600 µF ± (2.5% + 5)  @ 10 pF … 100 nF ,
    6 mF … 60 mF ± 10%  @ 1 µF … 10 µF
    Inductance measurement: ''
    Frequency measurement: 60 Hz … 10 MHz ± (0.01% + 5)  @ 0.001 Hz … 0.001 MHz
    Temperature measurement:
  • °C
  • -40  … 0 °C ± (2.0% + 30)  @ 0.1 °C
    >0  … 100 °C ± (1.0% + 30)  @ 0.1 °C
    >100  … 1000 °C ± 2.5%  @ 0.1 °C,
  • °F
  • -40  … 32 °F ± (2.5% + 50)  @ 0.1 °F
    >32  … 212 °F ± (1.5% + 50)  @ 0.1 °F
    >212  … 1832 °F ± (2.5% + 50)  @ 0.1 °F
    Automatic change of measuring ranges: ''
    hFE: ''
    Diode test: ''
    Sound signal of the continuity test: ''
    Checking TTL logic states: ''
    RS-232: ''
    USB: ''
    Main features:
  • True RMS – accurate measurement of the RMS current and voltage for any waveform,
  • NCV – electric field detection function,
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL – relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, readable LCD display with backlight,
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes a practical case
  • Power supply: Built-in battery 7.4V / 1800mAh, the set includes a 10V / 500mA power supply and a power adapter for charging the battery
    Weight: 0.53 kg
    Dimensions: 206  x 95  x 55 mm
    Manufacturer / Brand: UNI-T
    Guarantee: 2 years

    The UT-171B is a universal digital meter used to measure: voltage, current, resistance, inductance, capacitance, frequency, temperature and checking the correct operation of diodes

    The meter has the function of automatic change of measuring ranges, as well as the relative measurement mode

    Additionally, the UT-171B has an electric field detection (NCV) function

    Producent UNI-T

    EAN 5901890018265